Chapter 6 of the ibc details under what circumstances fire retardant treated wood is permitted and the acceptable exceptions to these rules.
Fire retardant treated wood ibc.
The code outlines the qualifications for fire retardant treatment the testing required to confirm the protection required strength adjustments and required fasteners for use.
Construction types i and ii are defined in ibc section 602 as having all elements of non combustible materials except where permitted in ibc section 603.
Fire retardant treated wood is any wood product which when impregnated with chemicals by a pressure process or other means during manufacture shall have when tested in accordance with astm e 84 or ul 723 a listed flame spread index of 25 or less and show no evidence of significant progressive combustion when the test is continued for an additional 20 minute period.
Construction types iii iv and v may be framed exclusively with wood but exterior walls in types iii and iv buildings are required to be fire retardant treated wood frtw.
Ibc section 602 3 type iv construction heavy timber ht fire retardant treated wood complying with section.
Whether you re using plywood or lumber dricon fire retardant treated frt wood has an unmatched record of protection against flame spread smoke development rot and decay.
Code requirements related to fire retardant treated wood are located in two places in the ibc.
The 2018 international building code clarifies that fire retardant treated wood frtw manufactured without using the pressure process must be impregnated with chemicals.
The international building code ibc defines the specifications for manufacturing and using fire retardant treated wood in construction.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
In section 2303 2 the ibc defines fire retardant treated wood as any wood product which when impregnated with chemicals by a pressure process or other means during manufacture shall have when tested in accordance with astm e 84 a listed flame spread index of 25 or less and show no evidence of.
Dricon introduced in 1981 is a class a fire retardant and preservative intended for wood used in interior weather protected construction this effective treatment is applied during manufacture creating a built.
New language in the 2018 ibc clarifies for building officials the regulations for using frtw in types i ii and iii construction which call for the use of non combustible.